International Journal of Biomedical Science 4(1), 64-69, Mar 15, 2008
Original Article


© 2005 Master Publishing Group

Inter- and Intra-Observer Concordance of Cyberpathology in Twenty-Five Cases

Tommy R. Tong1, Kam-cheong Lee1, Olivia Wai-hing Chan2, Ka-leung Au1, Wilson Man-shan Tsui3, Genevieve M. Learmonth4, Kelvin Ying-wai Leung1, Cecilia Siu-nga Wong1, Jessica Pik-man Lam1

1 Department of Pathology, Princess Margaret Hospital, Hong Kong

2 Department of Pathology, Alice Ho Miu-ling Nethersole Hospital, Hong Kong

3 Department of Pathology, Caritas Medical Centre, Hong Kong

4 Department of Pathology, Groote Schuur Hospital, and University of Cape Town, South Africa

Corresponding Author: Tommy R. Tong, AW Pathology Medical Group, 1700 ´C´ Street, Bakersfield, CA 93301. Tel: (661) 889-8218; Fax: (661) 885-5297; E-mail: tommy.tong@yahoo.com.


  ABSTRACT
INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
ACKNOWLEDGEMENT
REFERENCES


 ABSTRACT

  To study the feasibility of anatomical pathology consultation in cyberspace (cyberpathology) and to determine inter- and intra-observer concordance. Twenty-five consecutive cytology and histopathology cases are photographed using a digital camera placed against the eyepiece, and uploaded to an image-server in the Internet. Participants view the images, rate their confidence, and provide a diagnosis. They then view the original glass slides and provide a final diagnosis. The diagnoses are compared for inter- and intra-observer concordance. Participants are confident of their diagnoses based on viewing images on the Internet. The intra-observer concordance exceeds 95% individually, and 96% overall. Inter-observer concordance was 100% in a subset of cases. Cyberpathology as described is both available and affordable and is a valid alternative to slide-based anatomic pathology consultation.

KEY WORDS:   
cyberpathology, telecytology, telepathology, internet

 INTRODUCTION

  The practice of cytopathology and histopathology at a distance require the sharing of glass slides. A bottleneck exists at the level of slide transfer. In addition, cytology slides are often irreplaceable and cannot be sent to more than one recipient at a time. With the increasing inter-connectedness of the world and the arrival of multimedia-enabled Internet technology, this bottleneck is being assaulted from all sides. The impact of information technology on histopathology is recently reviewed (1-3).
  Telecytology and telepathology utilizing various direct network connections as well as the Internet has been the subject of many studies (4-6). However, to date it is not widely practiced except in experimental and pioneer settings. The reasons include the reluctance to view images on the monitor, the complexity and cost of initial setup and maintenance of the hardware and software, the difficulty of digitizing images, security issues and concerns over the accuracy of opinions rendered on digital images. The first is simply a habitual hurdle that endoscopists and laparoscopists have overcome - few continue to peer down the endoscope or laparoscope; they choose instead to adopt the more ergonomic way of viewing monitor screens hooked up to their scopes. Cytological and histopathological diagnosis entails examination of representative samples of a given specimen. This also applies to viewing images of tissue sections on paper or monitor in much the same way as an electron microscopist would. Obviously, the number of images viewed has an impact on the confidence of the pathologist and this is another hurdle that needs to be overcome by technology if telepathology were to prosper. Another major hurdle is in finding a solution to the complexity and cost of the overall process. These are some of the problems the authors faced when trying to practice telepathology.
  We describe a simple and economical telepathology setup that is easy to use, and takes advantage of freely available third-party Internet hosting service for images. We found the low cost, high quality, consumer type digital camera a very useful tool to cut down on the cost of the overall setup. In addition, we showed that pathologists were able to render accurate diagnoses based on viewing samples of digital images.

MATERIALS AND METHODS

  The hardware employed include a Nikon Labophot-2 microscope, an Olympus C2000Z digital camera, a Pentium II MMX IBM 300GL desktop computer with 192MB RAM and a LAN connection with Internet access behind a firewall. The software used includes Internet browser and imaging software that came with the digital camera (Camedia MasterTM 1.1).
  Twenty five consecutive cases of biopsies, surgical pathology specimens, bone marrow aspirate and fine needle aspiration cytology specimens that the author deemed to require a second opinion or an expert consultation in a normal pathology practice were collected over a 15-week period. Several pathologists participated, including two hematopathologists, who viewed the hematology cases for inter-observer concordance.
  Selected areas of diagnostic value, including random fields of various magnifications, were captured digitally at standard or high resolution in JPEG format using the method of Tse et al (7). Briefly, the camera was set to automatic exposure, aperture and focus. The flash was disabled. With the area of interest in focus, the camera lens was applied against one of the eyepieces and the image as seen in the LCD display of the camera assessed by the naked eye for adequacy of focus and illumination. The ´peeping hole´ effect was abolished using digital zoom to fill up the CCD or simply ignored in most cases. When the image appeared satisfactory, the shutter was pushed without shaking the camera.
  After the required images were photographed, they were transferred to the physical memory (hard-disk) of the computer by using the serial cable of the camera or by removing the storage medium (SmartmediaTM card) in the camera and downloading it to the computer with the help of a low cost card reader (FilandTM). The camera named images serially at the time of photography. In cases where the images need to be designated, the file names were changed manually. The quality of the digital images was determined empirically. Only images judged to be of sufficient quality or relevance are included in the study.
  With an active Internet connection, an account was first setup at http://www.kodakgallery.com by visiting the website and registering for the free service. The information required for registration included a valid email address, a user-defined password and the user′s firstname.
  After completing the registration, the images were uploaded using one of two user-friendly methods (browser upload or email attachment). The server processed the files and presented them at the "new" album. The images were then annotated or manipulated by following simple instructions. Image quality was again determined empirically and found to be satisfactory.
  Participants were then notified by clicking the "Share photos" tab followed by entering the participants′ email addresses and a message. The participants received emails with a hyperlink to the album. By clicking on the hyperlink, the album was displayed on the window of the Internet browser at the participants′ computer monitors. Clicking the thumbnail resulted in the display of the full sized image. A nice feature was "slideshow", which reduces significantly the number of mouse clicks, and hence user fatigue, if there were many images. The time taken to download the images was determined by the speed of the Internet connection.
  Participants were given a proforma to complete (Fig. 1). The proforma was adapted from figure 2 of a previous work (8). The participants filled out designated fields after viewing the images on the Internet. They were then given the glass slides. After viewing the slides, the final diagnosis was written in a separate box.
  The inter- and intra-observer concordance of diagnoses based on images and glass slides were analyzed. Also analyzed were responses to ´adequacy´ and ´confidence´.


View larger version :
[in a new window]
Figure 1: The proforma used in this study, as adapted from reference 8.
 

View larger version :
[in a new window]
Figure 2: Low magnification of H&E stained fine needle aspiration of papillary carcinoma of thyroid (case 2), depicting papillary fronds of neoplastic cells.
 

View larger version :
[in a new window]
Figure 3: High magnification of PAP stained fine needle aspiration of papillary carcinoma of thyroid (case 2), illustrating intranuclear pseudoinclusion (center), among other nuclear features of papillary carcinoma.

 RESULTS

  An average of 18 images were presented per case. The images of all 25 cases, except case 14 were judged satisfactory for evaluation (Table 1). The images from case 14 were of suboptimal quality and led to a wrong initial diagnosis of cytomegalovirus (CMV) infection in a case with adenocarcinoma. However, software enhancement (by adjusting contrast and brightness) of the digital images without re-photographing the case followed by re-evaluation by the same participant anonymously 3 months later resulted in a correct diagnosis. The concordance between diagnoses rendered on viewing the cyberimages and diagnoses based on viewing glass slides were 96 % and 100 %, before and after image enhancement (case 14). Otherwise, there was no major discrepancy between the image-based diagnoses and the slide-based diagnoses (Table 2). Figures 2 and 3 are examples of digital images as viewed by participants. Images used for this study can be accessed at the following website: www.kodakgallery.com. Login using dr10029@hotmail.com; password: 10029. After logging in enter the following URL in your browser and click a case number: www.geocities.com/tommytongmd/telepath/telepath.htm.
  Individuals differed in their use of "very confident" and "pretty confident". None of the participants were "not confident" about their image-based diagnoses. Most participants remarked that they adjusted quickly to rendering image-based diagnosis.
  The same degree of accuracy was seen in the fine needle aspiration cytology cases as the surgical or biopsy cases. When additional studies such as immunohistochemistry were performed (cases 12, 15, 17, 20, 24 and 25), participants commented that they were of value in arriving at an accurate classification or diagnosis of a clonal disease (multiple myeloma, case 15).

View this table:
[in a new window]
Table1 Adequacy of images.

View this table:
[in a new window]
Table 2 Intra-observer concordance and level of confidence.

 DISCUSSION

  Pathologists are keen on exploiting digital technology. Telepathology comes in two main forms. The most common form, as employed in the current study, consists of a static, non-interactive presentation of information and images (9-11). The other form of telepathology is dynamic, real-time, and interactive (5, 12-16). In robotic telepathology, motorized microscopes operated by remote computer users in real-time are employed. However, there are hardware limitations as well as time-zone differences to address for this methodology, not to mention the costs involved. If there is more than one slide, a person needs to stand by the microscope to change slides. This method is ill suited for locations with significant time zone differences. Alternative to robotic telepathology, real-time telepathology are also practiced using web-based video-conferencing technology (17, 18). Virtual microscopy, employing fully digitized glass slides, serves to replace the microscope but has its own limitations in the setting of pathology consultation.
  The technique used in the current study is made possible by the use of digital photography using consumer grade digital camera and proprietary "dot.com" innovations in sharing images on the Internet. The advantage is that it combines the ease of use of the digital camera, and the ability to share images with any number of invited consultants. This ability to share images is particularly suited for external quality assurance activity in that all participants see exactly the same images.
  This study started with skeptical participants whose confidence increased with use. Although the images were of low resolution, a target diagnosis could still be made for both histological and cytological materials. Both common and rare cases were diagnosed accurately based on viewing representative images on the computer monitor (Table II). Our experience agrees with published results of similar studies (19, 20).
  The number of images appeared to be important in histopathological as well as in cytological materials. One of the 5 FNA cytology cases (case 5) was diagnosed as "suspicious for adenocarcinoma" based on the 13 images. The suspicion might be removed if more images had been submitted.
  Case 11 (Hodgkin lymphoma) showed minor discrepancy between the cytological and histopathological diagnosis. This phenomenon is observed in cytology owing to limitation of sampling rather than being a problem specific to telecytology. The concordance between the telecytology diagnoses and the glass slide diagnoses testifies to the argument. Three participants saw the hematology cases and case 25 and all arrived at essentially the same conclusions based on viewing the images. These cases addressed inter-observer concordance, which was also studied by others (21-23). When inter-observer and intra-observer concordances are compared, the former shows larger discrepancy (16).
  Because any number of participants may be invited to view exactly the same images, this setup is suitable for quality assurance activities such as mandatory second opinion (24). Virtual microscopy of digital slides on other media such as optical disk may also be suitable for this kind of activity (19).
  For Internet security, patients in this study were identified by case numbers. If patient demographics need to be transmitted to the remote user, security can be assured by using facsimile or separate email employing encryption technology (20).
  This study demonstrates that histopathological or cytological diagnosis is possible based on viewing representative static images on a computer monitor. The high intra-observer concordance (100%) compares favorably with that of other studies, which range from 80 % to 100 % (12, 18, 24-32). This study further described an easy and economical cyberpathology setup that demands minimal knowledge of the workings of the Internet and a small investment in hardware. In addition to consultation, we think this method is also suitable for external quality assurance activities.

 REFERENCES

    1. Cross SS, Dennis T, Start RD. Telepathology: current status and future prospects in diagnostic histopathology. Histopathology 2002; 41(2):91-109.
    2. Leong FJ. Practical applications of Internet resources for cost-effective telepathology practice. Pathology 2001; 33(4):498-503.
    3. Weinstein RS, Descour MR, Liang C, et al. Telepathology overview: from concept to implementation. Hum Pathol 2001; 32(12):1283-99.
    4. Lee E, Kim I, Choi J, et al. Practical telepathology using a digital camera and the internet. Telemed J E Health 2002; 8(2):159-65.
    5. Leong FJ, Nicholson AG, McGee JO. Robotic telepathology: efficacy and usability in pulmonary pathology. J Pathol 2002; 197(2):211-7.
    6. Liang WY, Hsu CY, Lai CR, Ho DM, Chiang IJ. Low-cost telepathology system for intraoperative frozen-section consultation: our experience and review of the literature. Hum Pathol 2008; 39(1):56-62.
    7. Tse CC. Anatomic pathology image capture using a consumer-type digital camera. Am J Surg Pathol 1999; 23(12):1555-8.
    8. Briscoe D, Adair CF, Thompson LD, et al. Telecytologic diagnosis of breast fine needle aspiration biopsies. Intraobserver concordance. Acta Cytol 2000; 44(2):175-80.
    9. Marchevsky AM, Dulbandzhyan R, Seely K, Carey S, Duncan RG. Storage and distribution of pathology digital images using integrated web-based viewing systems. Arch Pathol Lab Med 2002; 126(5):533-9.
    10. Pak HS. Teledermatology and teledermatopathology. Semin Cutan Med Surg 2002; 21(3):179-89.
    11. Tucker JH, Busch C, Spatz A, Wells C, Brugal G. An experimental inter-expert telepathology network using static imaging. J Clin Pathol 2001; 54(10):752-7.
    12. Kaplan KJ, Burgess JR, Sandberg GD, Myers CP, Bigott TR, Greenspan RB. Use of robotic telepathology for frozen-section diagnosis: a retrospective trial of a telepathology system for intraoperative consultation. Mod Pathol 2002; 15(11):1197-204.
    13. Demichelis F, Barbareschi M, Boi S, et al. Robotic telepathology for intraoperative remote diagnosis using a still-imaging-based system. Am J Clin Pathol 2001; 116(5):744-52.
    14. Nehal KS, Busam KJ, Halpern AC. Use of dynamic telepathology in Mohs surgery: a feasibility study. Dermatol Surg 2002; 28(5):422-6.
    15. Schroeder JA, Voelkl E, Hofstaedter F. Ultrastructural telepathology--remote EM-diagnostic via Internet. Ultrastruct Pathol 2001; 25(4):301-7.
    16. Singh N, Akbar N, Sowter C, Lea KG, Wells CA. Telepathology in a routine clinical environment: implementation and accuracy of diagnosis by robotic microscopy in a one-stop breast clinic. J Pathol 2002; 196(3):351-5.
    17. Marchevsky AM, Lau SK, Khanafshar E, et al. Internet teleconferencing method for telepathology consultations from lung and heart transplant patients. Hum Pathol 2002; 33(4):410-4.
    18. Pan CC, Liang WY, Huang CW, Chiang H. Diagnosing minimal adenocarcinoma on prostate needle biopsy by real-time dynamic telepathology through the internet: evaluation of an economic technology for remote consultation. Hum Pathol 2002; 33(2):242-6.
    19. Leong FJ, McGee JO. Automated complete slide digitization: a medium for simultaneous viewing by multiple pathologists. J Pathol 2001; 195(4):508-14.
    20. Strauss JS, Felten CL, Okada DH, Marchevsky AM. Virtual microscopy and public-key cryptography for Internet telepathology. J Telemed Telecare 1999; 5(2):105-10.
    21. Alli PM, Ollayos CW, Thompson LD, et al. Telecytology: intraobserver and interobserver reproducibility in the diagnosis of cervical-vaginal smears. Hum Pathol 2001; 32(12):1318-22.
    22. Cross SS, Burton JL, Dube AK, et al. Offline telepathology diagnosis of colorectal polyps: a study of interobserver agreement and comparison with glass slide diagnoses. J Clin Pathol 2002; 55(4):305-8.
    23. Odze RD, Goldblum J, Noffsinger A, Alsaigh N, Rybicki LA, Fogt F. Interobserver variability in the diagnosis of ulcerative colitis-associated dysplasia by telepathology. Mod Pathol 2002; 15(4):379-86.
    24. Kronz JD, Westra WH, Epstein JI. Mandatory second opinion surgical pathology at a large referral hospital. Cancer 1999; 86(11):2426-35.
    25. Della Mea V, Cataldi P, Boi S, Finato N, Dalla Palma P, Beltrami CA. Image sampling in static telepathology for frozen section diagnosis. J Clin Pathol 1999; 52(10):761-5.
    26. Montironi R, Thompson D, Scarpelli M, et al. Transcontinental communication and quantitative digital histopathology via the Internet; with special reference to prostate neoplasia. J Clin Pathol 2002; 55(6):452-60.
    27. Chorneyko K, Giesler R, Sabatino D, et al. Telepathology for routine light microscopic and frozen section diagnosis. Am J Clin Pathol 2002; 117(5):783-90.
    28. Allen EA, Ollayos CW, Tellado MV, et al. Characteristics of a telecytology consultation service. Hum Pathol 2001; 32(12):1323-6.
    29. Fisher SI, Nandedkar MA, Williams BH, Abbondanzo SL. Telehematopathology in a clinical consultative practice. Hum Pathol 2001; 32(12):1327-33.
    30. Minervini MI, Yagi Y, Marino IR, et al. Development and experience with an integrated system for transplantation telepathology. Hum Pathol 2001; 32(12):1334-43.
    31. Piccolo D, Soyer HP, Burgdorf W, et al. Concordance between telepathologic diagnosis and conventional histopathologic diagnosis: a multiobserver store-and-forward study on 20 skin specimens. Arch Dermatol 2002; 138(1):53-8.
    32. Williams BH, Mullick FG, Butler DR, Herring RF, O'Leary T J. Clinical evaluation of an international static image-based telepathology service. Hum Pathol 2001; 32(12):1309-17.
ContentFullText

The exquisite patterns on the luxury replica watches dial, the date display window at replica watches six o'clock, and the black sculpted Arabic numerals demonstrate the replica rolex exquisite craftsmanship of rolex watches uk the fine watchmaking style.