Received- March 12, 2009; Accepted- May 11, 2009
 International Journal of Biomedical Science 5(2), 175-180, Jun 15, 2009
Original Article


© 2005 Master Publishing Group

Development and Validation of Pregabalin in Bulk, Pharmaceutical Formulations and in Human Urine Samples by UV Spectrophotometry

Rajinder Singh Gujral, Sk Manirul Haque, Prem Shanker

Vardhman Chemtech Limited, Nimbua, Dera Bassi, Mohali, Punjab, India

Corresponding Author: Rajinder Singh Gujral, Director, Vardhman Chemtech Ltd, Nimbua, Dera Bassi, Mohali, Punjab, India. Tel: +91-9914013470; E-mail: gujral@vardhmanchemtech.com.

Running title: Determination of Pregabalin by UV


  ABSTRACT
INTRODUCTION
EXPERIMENTAL
METHODS
METHOD VALIDATION
RESULTS AND DISCUSSIONS
CONCLUSIONS
REFERENCES


 ABSTRACT

A simple and sensitive UV spectrophotometric method was developed and validated for the determination of pregabalin in bulk, pharmaceutical formulations and in human urine samples. The method was linear in the range of 0.5-5.0 µg/ml. There is no generally accepted method for the determination of pregabalin. The absorbance was measured at 210 nm. The method was validated with respect to accuracy, precision, specificity, ruggedness, and robustness, limit of detection and limit of quantitation. This method was used successfully for the quality assessment of five pregabalin drug products and in human urine samples with good precision and accuracy. This is found to be simple, specific, precise, accurate, reproducible and low cost UV Spectrophotometric method.

KEY WORDS:    pregabalin; validation; bulk drug, pharmaceutical formulations; human urine samples; uv

 INTRODUCTION

   Pregabalin (PGB) is a new active substance known chemically as (S)-3-amino methyl-5-methyl hexanoic acid and is structurally related to the naturally occurring amino acids L - leucine and gamaa aminobutyric acid (GABA) (Fig. 1). It is a white to off - white crystalline, non - hygroscopic and water soluble (freely soluble below pH-3.7) powder. It contains one chiral centre, but is synthesized as the single enantiomer S. PGB exists as a single anhydrous and not solvated crystal form.

   PGB is a new anticonvulsant and analgesic medication that was recently approved for adjunctive treatment of partial seizures in adults (1-4) in both the United States and Europe and for the treatment of neuropathic pain from postherpetic neuralgia and diabetic neuropathy. It is both structurally and pharmacologically related to the anticonvulsant and analgesic medication gabapentin (Fig. 2).

   The mechanism of action is still unclear, pregabalin decreases central neuronal excitability by binding to an auxiliary subunit (α2-δ protein) of a voltage - gated calcium channel on neurons in the central nervous system. PGB reduces the release of several neurotransmitters include glutamate, norepinephrine, Substance P, and calcitonin gene related peptide from certain brain tissues and also reduce calcium influx in synaptosomes.

   Pregabalin undergoes minimal metabolism in human with unchanged parent representing the majority (≥90 %) of drug - derived material (5). This contrasts with gabapentin, which is absorbed via a capacity limited L - amino acid transport system from the proximal small bowel into the blood stream (6-7).

   The therapeutic importance of Pregabalin was behind the development of numerous methods for its determination. The methods adapted to the analysis of PGB include high - performance liquid chromatography (HPLC) (8), liquid chromatography - mass spectrophotometry (LC-MS) (9-10) and spectrofluorimetry (11). In addition, these methods require long and tedious pretreatment of the samples and laborious clean up procedures prior to analysis. An official monograph of PGB does not exist in any pharmacopoeia and determination of PGB in bulk and pharmaceutical formulations has not been yet described. Therefore, it is very imperative to develop a simple and suitable analytical method for the determination of PGB in bulk and pharmaceutical formulations. UV - Visible spectrophotometry is the technique of choice in research laboratories, hospitals and pharmaceutical industries due to its low cost and inherent simplicity.

   This paper reports a simple, sensitive and accurate spectrophotometric method for the determination of PGB. The method is based on the direct measurement of native absorbance of the drug at 210 nm against the reagent blank. The proposed method was extended to the determination of PGB in bulk, pharmaceutical formulations and in human urine samples.


View larger version :
[in a new window]
Figure 1. Structure of Pregabalin.
 

View larger version :
[in a new window]
Figure 2. Structure of Gabapentin.

 EXPERIMENTAL

   Apparatus

   Spectral runs were made on UV 3000+ UV/VIS spectrophotometer (LABINDIA®, Mumbai, India) with 1 cm matched glass cell.

   Materials and Reagents

   Determination of appropriate UV wavelength

   A suitable wavelength was required for the determination of Pregabalin. The appropriate wavelength for the determination of PGB was determined by wavelength scanning over the range 190-450 nm with a UV 3000+ UV/VIS spectrophotometer (LABINDIA®, Mumbai, India).

   Standard PGB Solution

   A stock solution of PGB (50 µg/ml) was prepared by dissolving 5 mg PGB in 100 ml volumetric flasks with double distilled water. The stock solution (50 µg/ml) was used to prepare the working solutions by suitable dilutions with distilled water. The solutions were stable at least 10 days in room temperature.

 METHODS

   Procedure for the determination of PGB

   Aliquots of stock solution (50 µg/ml) were transferred into a set of 50 ml volumetric flasks and volumes were completed to the mark with distilled water to produce solutions in the concentration range 0.5-5.0 µg/ml. Absorbance was measured at 210 nm (Fig. 3) against the reagent blank. Calibration graphs were constructed by plotting absorbance against the final concentration of PGB.

   Procedure for determination of PGB in pharmaceutical formulations

   One capsule (claiming 75 mg of Pregabalin) was accurately weighed and finely powdered. A quantity of the powder equivalent to 5 mg of PGB was extracted by shaking with 20 ml of distilled water, followed by another two extractions each with 10 ml distilled water. After passing through a 0.45 μm Millipore filter, the solution was diluted with distilled water to obtain a concentration of about 50 µg/ml. It was further diluted according to the need and then analyzed following the proposed procedures. The nominal content of the capsule was calculated either from the previously plotted calibration graphs or using regression equation.

   Procedure for determination of PGB in human urine samples

   Aliquot volumes of human urine samples were transferred into small separating funnel. 10 ml of carbonate buffer pH-9.4 was added and solution was mixed well. The solution was then extracted with 2 × 10 ml diethyl ether. The ether extract was collected and evaporated. The residue was dissolved in 10 ml distilled water and above general procedure was then followed. The amount of PGB was obtained from the calibration graphs or corresponding regression equation.


View larger version :
[in a new window]
Figure 3. Absorption spectra of Pregabalin (5.0 µg/ml).

 METHOD VALIDATION

   The method was validated for selectivity, linearity, precision, accuracy, recovery and stability according to the principles of the Food and Drug Administration (FDA) industry guidance (12). Validation of analytical procedures is a vital aspect not just for regulatory purposes, but also for their efficient and reliable long - term application. The ICH guidelines achieved a great deal in harmonizing the definitions of required validation parameters, their calculation and interpretation. It is the responsibility of the analyst to identify parameters which are relevant to the performance of given analytical procedure as well as to design proper validation protocols including acceptance criteria and to perform an appropriate evaluation. The International Conference on the Harmonization of the Technical Requirements for Registration of Pharmaceuticals for Human Use has harmonized the requirements in two guidelines (13, 14). The first one summarizes and defines the validation characteristics needed for various types of test procedures, the second one extends the previous test to include the experimental data required and some statistical interpretation. These guidelines serve as a basis worldwide both for regulatory authorities and industry and bring the importance of a proper validation to the attention of all those involved in the process of submission. Nowadays, the validation characteristics needed for the various test procedures and their general requirements are well understood. The essential question to be answered is on the suitability of the calibration mode to be used in the test procedure. It should be noted that in most cases only a qualitative statement is needed.

   The stability of the working PGB sample solutions at room temperature was evaluated with the help of UV spectra. The specificity and selectivity of the proposed method was evaluated by estimating the amount of PGB in the presence of common excipients lactose monohydrate, corn, starch, talc and methyl cobalamin.

   The linearity of the proposed method was constructed for Pregabalin reference standard solution by plotting concentration of the compound versus the absorbance. The linearity was evaluated by linear regression analysis, which was calculated by the least square regression method. The parameters LOD and LOQ were determined on the basis of response and slope of the regression equation. The accuracy and precision of the method was evaluated within the linear range based on the analysis of PGB reference standard samples and pharmaceutical formulations at 2.0, 3.5 and 5.0 µg/ml. Five independent analysis were performed at each concentrations level within one day (intraday precision) as well as for five consecutive days (interday precision). The accuracy was ascertained by recovery studies using the standard addition method. The proposed method was used for estimation of PGB from capsules after spiking with 50, 200 and 350 % additional pure drug. The amount of PGB was determined from the regression equation.

 RESULTS AND DISCUSSIONS

   In order to investigate the appropriate wavelength for the determination of PGB, solution of PGB was scanned by UV spectrophotometer in the range of 190 - 450 nm. The maximum absorbance was observed at 210 nm and this wavelength was fixed for the analysis of Pregabalin.

   The absorbance - concentration plot for the proposed method was found to be rectilinear over the range of 0.5-5.0 µg/ml. Linear regression analysis of calibration data gave the regression equation cited in Table 1 with correlation coefficients close to unity. Statistical analysis of regression lines were made regarding the standard deviation of residuals (Sx/y), standard deviation of slopes (Sb) and standard deviation of intercepts (Sa) and the values are summarized in Table 1.

   The within day precision assays were carried out through replicate analysis (n=5) of PGB corresponding to 2.0, 3.5 and 5.0 µg/ml. The interday precision was evaluated through replicate analysis of the pure drug samples for five consecutive days at the same concentration levels as used in within day precision. The results of these assays are reported in Table 2. As can be seen from Table 2 that the recovery and RSD values for within day precision were always lower than 100.057 % and 0.891 % ; recovery and RSD values for interday precision were lower than 100.056% and 0.968 %. The precision results are satisfactory. The intraday and interday precision assays were also carried for PGB in pharmaceutical formulations. The results are summarized in Table 3. As can be seen from Table 3 that the recovery and RSD values were in the ranges 99.920 to 100.171 %; 0.258 to 0.968 % and 99.801 to 100.199 %  ; 0.203 to 1.136  % respectively for intraday and interday precision.

   The proposed method was used for estimating of PGB from capsules after spiking with 50, 200 and 350 % of additional pure drug. The results are reported in Table 4. As can be seen from Table 4 that the recovery and RSD values were in the ranges 99.920 to 100.027 % and 0.152 to 0.923 %. The selectivity of the proposed method was ascertained by analyzing standard PGB in the presence of excipients such as lactose monohydrate, corn, starch, talc and methyl cobalamin. It was observed that the excipients did not interfere with the proposed method.

   The proposed method was further extended to the in vitro determination of PGB in spiked human urine samples. In neuropathic patients, PGB is orally given in doses of 150 to 600 mg per day, with an associated mean of around 123 µg.hr/ml.  Pregabalin undergoes minimal metabolism in human with unchanged parent representing ≥90% of drug derived in urine. This concentration fell well within working range of proposed method. The calibration graphs were constructed by plotting absorbance versus increasing concentrations of PGB in spiked human urine samples over the concentration range 0.5-5.0 µg/ml. The results (Table 5) are satisfactorily accurate and precise.

View this table:
[in a new window]
Table 1. Summary of optical and regression characteristics of the proposed method


View this table:
[in a new window]
Table 2. Summary of accuracy and precision results of the proposed method in pure form


View this table:
[in a new window]
Table 3. Summary of accuracy and precision results of the proposed method in pharmaceutical formulations


View this table:
[in a new window]
Table 4. Summary of data for the determination of pregabalin in pharmaceutical preparations by standard addition method


View this table:
[in a new window]
Table 5. Application of the proposed UV method to the determination of pregabalin in human urine samples

 CONCLUSIONS

   The proposed method does not require any laborious clean up procedure before measurement. In addition, the method has wider linear dynamic range with good accuracy and precision. The method shows no interference from the common excipients and additives. Since in human unchanged parent representing ≥ 90% of drug is derived in urine, this method can be used for estimating unabsorbed PGB in urine samples by very simple, cost affective, fast and efficient method. This may help in analyzing affectivity of this drug in human beings during treatment. Therefore, it is concluded that the proposed method is simple, sensitive and rapid for the determination of pregabalin in bulk, pharmaceutical formulations and in human urine samples.

 REFERENCES

    1. D.M. Tassone, E. Boyce, J. Guyer, D. Nuzum. Clin. Ther. 2007; 29: 26-48.
    2. K. Hamandi, J.W. Sander. Seizure. 2006; 15: 73-78.
    3. R. Freynhagen, K. Strojek, T. Griesing, E. Whalen, et al. Pain. 2005; 115: 254-263.
    4. U. Sharma, J. Young, L. LaMoreaux. Pain. 2005; 6:  S29.
    5. D. Wesche, H. Bockbrader. Pain. 2005; 6: 29.
    6. B. H. Stewart, A. R. Kugler, P. R. Thompson, H. N. Bockbrader. Pharm. Res. 1993; 10: 226-228.
    7. D. Turck, K. O. Vollmer, H. Bockbrader. Eur. J. Clin. Pharmacol. 1989; 36: 310.
    8. T. A. C. Vermeij, P. M. Edelborek. J. Chromatogr. B. 2004; 810: 297-303.
    9. U. Mandal, A. K. Sarkar, K. V. Gowda, S. Agarwal, et al.Chromatogra. 2008; 67: 237-243.
    10. R. Oertel, N. Arenz, J. Pietsch, W. Kirch. J. Sep.  Sci. 2008; 32: 238-243.
    11. A. Önal, O. Sagirli. Spectrochim. Acta Part A: Molecular and Biomol. Spectros. 2009; 72: 68-71.
    12. Food and Drug Administration of the United States, Guidance for industry - Bioanalytical Method Validation, U.S. Department of Health and Human Services, Centre for Drug Evaluation and Research (CDER), Center for Veterinary Medicine (CVM). 2001 http://www.fda.gov/cder/guidance/index.htm.
    13. International Conference on the Harmonization of the Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) Q2A: Validation of Analytical Methods (Definitions and Terminology). 1994.
    14. ICH: Q2B Analytical Validation - Methodology. 1996.